Apr
21

How do I install a Permeate Pump to my RO system?

By h2osplashwaterfilters

Answer:

You will mount the Permeate Pump on the wall next to the Reverse Osmosis system. The Permeate “out” on the membrane housing (good RO water) will go to the Permeate “in” on the Permeate Pump. The Permeate “out” from the Permeate pump will go to the Permeate “in” on the ASO valve.Currently (before you install the new Permeate Pump) the blue tubing goes from the Permeate “out” on the membrane housing directly to the “in” on the ASO valve. What you are doing is installing the Permeate Pump between the membrane housing and the ASO valve.

Now for the drain line. Just as in the situation of the good RO water, the drain water is routed through the Permeat Pump. So from the membrane housing “out” for drain water, you run the black tubing from the membrane housing to the “in” for the drain on the Permeate Pump.Then from the “out” for the drain on the Permeate Pump, the black tubing goes to your drain saddle.

For addition information and diagrams, go to our “Permeate Pump Installation Instructions” on our web siteĀ  www.waterfilteruniversity.com